Turnkey 機房/數據中心Turnkey Data Centre / Server Room
一站式設計與建造,涵蓋發電機、監測、漏水偵測、極早期煙感、機櫃、FM200、配線、配電、ATS、架空地板及機房搬遷等。One-stop design and build covering generators, monitoring, leak detection, aspirating smoke detection, racks, FM200, cabling, electrical distribution, ATS, raised flooring and computer room relocation.
常見挑戰The challenge
新建或改造機房涉及電力、製冷、消防、布線、監測及建築等多個工種。介面多、協調難,任何一環延誤都會影響整體進度及風險。Building or upgrading a server room involves power, cooling, fire protection, cabling, monitoring and architectural trades. Many interfaces make coordination hard, and a delay in any one of them affects the whole programme and its risk.

我們的工作Our scope of work
- 發電機系統Generator systems
- 警報及環境監測系統Alert and environmental monitoring
- 漏水偵測系統Water leak detection
- 極早期煙霧偵測(Aspirating)Aspirating smoke detection
- 伺服器/網絡機櫃Server / network racks
- FM200 氣體滅火系統FM200 fire suppression
- 光纖/網線布線Fibre / Ethernet cabling
- PDU 及配電(電氣工程)PDU and electrical distribution
- 自動切換開關(ATS)Automatic transfer switches (ATS)
- 架空地板Raised access floor
- UPS 及精密製冷整合UPS and precision cooling integration
- 冷/熱通道封閉Aisle containment
- 保安/門禁Security / controlled access
- 機房搬遷Computer room relocation
- Green DC 設計Green Data Centre design
由初步設計到詳細設計From preliminary to detailed design
- 初步設計Preliminary design
- 制定規格Specification
- 詳細設計Detailed design
- 綠色數據中心(Green DC)設計Green Data Centre initiative
- 以 Reliability Level 3 設施設計為導向Facilities designed towards Reliability Level 3
設計考慮範疇Design disciplines covered
- 消防Fire protection
- 電纜橋架Cable trays
- 天花及建築設計Ceiling & architectural design
- 保安/門禁Security / controlled access
- 布線及跳線Cabling & patching
- UPS 及電氣系統UPS & electrical system
- 電池Batteries
- 市電供應Utility source
- 樓面承重及地台Floor loading & floor tiles
- 機櫃設計Rack design
- 機械系統Mechanical system
- 儀表及控制系統Instrumentation & control
- 暖通空調(HVAC)HVAC
- 架空地板設計Raised floor design
- 電訊/電力線槽Telecom / power cable trays
- 燃油及發電機Fuel & generator
- 企業指揮中心Enterprise command centre
- 高密度綠色數據中心High-density Green DC
清晰的交付內容Clear, documented deliverables
項目管理Project management
- 整體項目實施計劃Overall project implementation plan
- 進度會議Progress meetings
- 項目狀態報告Project status reports
- 變更控制管理Change control management
現場實施Site implementation
- 設備付運及安裝Delivery and installation of equipment
- 詳細測試及調試,並提供報告Detailed testing and commissioning, with report
- 操作手冊Operation manual
- 竣工圖則(As-built drawings)As-built drawings如設備佈局、架空地板、電氣原理、空調、FM200 及監測系統圖e.g. equipment layout, raised floor, electrical schematics, A/C, FM200 and monitoring system diagrams
- 現場用戶技術轉移On-site user skill transfer session
電腦機房搬遷服務Computer room relocation services
由搬遷規劃、設備拆裝及搬運,到新機房安裝、測試及重新上線,按客戶需要安排,減少對業務的影響。From relocation planning, decommissioning and moving through to installation, testing and re-commissioning at the new site—arranged around your operations to minimise disruption.
查看工程案例See our job references
工程現場From our sites




相片為本公司工程現場實景,已移除可識別客戶的資料。Photos are from our project sites, with client-identifying details removed.
一站式整合其他機房系統Integrated with the rest of your facility
UPS/電力UPS & Power
供應及整合 UPS 系統,支援關鍵負載穩定供電,並可配合安裝、測試與後續保養。Supply and integration of UPS systems for critical loads, with installation, commissioning and ongoing maintenance support.
了解更多Learn more精密製冷 CRAC/InRowPrecision Cooling (CRAC / InRow)
提供 CRAC 及 InRow 製冷方案,協助控制機房溫度與濕度。CRAC and InRow cooling solutions to help manage temperature and humidity in data halls.
了解更多Learn more7×24 維護及預防性保養7×24 Maintenance & Preventive Care
全年無休緊急支援,目標最快約 2 小時到場;可提供預防性保養,以及 12 個月或可選 36 個月零件與人工保固。Year-round emergency support with up to about 2 hours on-site response, plus preventive maintenance and 12-month or optional 36-month parts-and-labour warranty.
了解更多Learn more正在規劃機房或數據中心項目?Planning a data centre or server room project?
告訴我們場地情況和需求,我們會建議合適的方案及下一步。Tell us about your site and requirements, and we will recommend a suitable approach and next steps.
- 辦公室Office+852 3621 0375
- 傳真Fax+852 3628 2542
- 電郵Emailinfo@solutioneng.com.hk