服務Services

Turnkey 機房/數據中心Turnkey Data Centre / Server Room

一站式設計與建造,涵蓋發電機、監測、漏水偵測、極早期煙感、機櫃、FM200、配線、配電、ATS、架空地板及機房搬遷等。One-stop design and build covering generators, monitoring, leak detection, aspirating smoke detection, racks, FM200, cabling, electrical distribution, ATS, raised flooring and computer room relocation.

常見挑戰The challenge

新建或改造機房涉及電力、製冷、消防、布線、監測及建築等多個工種。介面多、協調難,任何一環延誤都會影響整體進度及風險。Building or upgrading a server room involves power, cooling, fire protection, cabling, monitoring and architectural trades. Many interfaces make coordination hard, and a delay in any one of them affects the whole programme and its risk.

機房配電工程:配電箱、線槽及電纜
服務範圍What we do

我們的工作Our scope of work

  • 發電機系統Generator systems
  • 警報及環境監測系統Alert and environmental monitoring
  • 漏水偵測系統Water leak detection
  • 極早期煙霧偵測(Aspirating)Aspirating smoke detection
  • 伺服器/網絡機櫃Server / network racks
  • FM200 氣體滅火系統FM200 fire suppression
  • 光纖/網線布線Fibre / Ethernet cabling
  • PDU 及配電(電氣工程)PDU and electrical distribution
  • 自動切換開關(ATS)Automatic transfer switches (ATS)
  • 架空地板Raised access floor
  • UPS 及精密製冷整合UPS and precision cooling integration
  • 冷/熱通道封閉Aisle containment
  • 保安/門禁Security / controlled access
  • 機房搬遷Computer room relocation
  • Green DC 設計Green Data Centre design
設計Design

由初步設計到詳細設計From preliminary to detailed design

  • 初步設計Preliminary design
  • 制定規格Specification
  • 詳細設計Detailed design
  • 綠色數據中心(Green DC)設計Green Data Centre initiative
  • 以 Reliability Level 3 設施設計為導向Facilities designed towards Reliability Level 3

設計考慮範疇Design disciplines covered

  • 消防Fire protection
  • 電纜橋架Cable trays
  • 天花及建築設計Ceiling & architectural design
  • 保安/門禁Security / controlled access
  • 布線及跳線Cabling & patching
  • UPS 及電氣系統UPS & electrical system
  • 電池Batteries
  • 市電供應Utility source
  • 樓面承重及地台Floor loading & floor tiles
  • 機櫃設計Rack design
  • 機械系統Mechanical system
  • 儀表及控制系統Instrumentation & control
  • 暖通空調(HVAC)HVAC
  • 架空地板設計Raised floor design
  • 電訊/電力線槽Telecom / power cable trays
  • 燃油及發電機Fuel & generator
  • 企業指揮中心Enterprise command centre
  • 高密度綠色數據中心High-density Green DC
項目交付Project deliverables

清晰的交付內容Clear, documented deliverables

項目管理Project management

  • 整體項目實施計劃Overall project implementation plan
  • 進度會議Progress meetings
  • 項目狀態報告Project status reports
  • 變更控制管理Change control management

現場實施Site implementation

  • 設備付運及安裝Delivery and installation of equipment
  • 詳細測試及調試,並提供報告Detailed testing and commissioning, with report
  • 操作手冊Operation manual
  • 竣工圖則(As-built drawings)As-built drawings如設備佈局、架空地板、電氣原理、空調、FM200 及監測系統圖e.g. equipment layout, raised floor, electrical schematics, A/C, FM200 and monitoring system diagrams
  • 現場用戶技術轉移On-site user skill transfer session
機房搬遷Relocation

電腦機房搬遷服務Computer room relocation services

由搬遷規劃、設備拆裝及搬運,到新機房安裝、測試及重新上線,按客戶需要安排,減少對業務的影響。From relocation planning, decommissioning and moving through to installation, testing and re-commissioning at the new site—arranged around your operations to minimise disruption.

查看工程案例See our job references
新建成的 Turnkey 機房,採用 InRow 製冷及通道封閉
項目實景Project photos

工程現場From our sites

相片為本公司工程現場實景,已移除可識別客戶的資料。Photos are from our project sites, with client-identifying details removed.

聯絡我們Contact us

正在規劃機房或數據中心項目?Planning a data centre or server room project?

告訴我們場地情況和需求,我們會建議合適的方案及下一步。Tell us about your site and requirements, and we will recommend a suitable approach and next steps.