Smart-UPS On-Line SRTSmart-UPS On-Line SRT

APC SRT6KRMXLI 替換電池:APCRBC140APC SRT6KRMXLI replacement battery: APCRBC140

替換電池對照、更換須知及相關 APC 官方通告。資料來自 APC/Schneider Electric 官方公開資料;未確認的項目標示「請向我們確認」。Replacement battery, replacement notes and related official APC notices, from official APC / Schneider Electric public information. Unconfirmed items are marked “Please confirm with us”.

電池對照Battery lookup

適用替換電池Compatible replacement battery

UPS 型號UPS model替換電池Replacement battery數量Qty更換方式/熱插拔Replacement / hot-swap官方來源Source
Smart-UPS On-Line SRTSmart-UPS On-Line SRT
SRT6KRMXLIAPCRBC1402 個模組2 modules1可熱插拔(無需關機;更換期間沒有電池後備)Hot-swappable (no shutdown; no battery backup during the swap)990-5181B · FA333556
  • 990-5181B 亦列出 SRT5KXLJ(日本型號)使用 APCRBC140J,以及 SURT 系列相關型號,香港一般不適用。990-5181B also lists SRT5KXLJ (Japanese model) using APCRBC140J, and related SURT models; these generally do not apply in Hong Kong.

需要 SRT6KRMXLI 電池報價或更換服務?Need a battery quotation or replacement for the SRT6KRMXLI?

告訴我們 UPS 型號及數量,我們會確認電池型號並提供正式報價。Tell us your UPS model and quantity, and we will confirm the battery model and send a formal quotation. info@solutioneng.com.hk

查詢/報價Enquire / quote
更換指引Replacement guide

換電池須知及步驟Battery replacement notes and steps

安全須知(官方手冊摘要)Safety notes (summary of official manuals)

  • 電池應由熟悉電池及相關防護措施的人員更換,或在其監督下進行。Batteries should be replaced by, or under the supervision of, personnel familiar with batteries and the required precautions.
  • 至少每 5 年更換一次電池,或在電池壽命終結時更換(以較早者為準)。Replace the batteries at least every 5 years or at the end of their service life, whichever comes first.
  • UPS 顯示需要更換電池時,應立即更換。Replace the battery immediately when the UPS indicates that replacement is needed.
  • 如出現電池過熱,或有電解液洩漏的跡象:If a battery overheats or shows signs of electrolyte leakage:
    • 立即關掉 UPS,拔除 AC 輸入,並斷開電池。Turn off the UPS immediately, unplug the AC input and disconnect the batteries.
    • 更換電池之前不要再使用該 UPS。Do not use the UPS again until the batteries have been replaced.
  • 必須使用與原裝相同數量及型號的電池。Use the same number and model of batteries as originally installed.
  • 更換電池或加裝外置電池組時,所有使用超過 1 年的電池模組(包括外置電池組 XLBP 內的模組)都應一併更換。When replacing batteries or adding external battery packs, replace every battery module more than 1 year old at the same time (including modules in XLBP external packs).
  • 操作前除下手錶、戒指等金屬飾物;使用絕緣手柄工具;戴上橡膠手套及穿著橡膠靴。Before starting, remove watches, rings and other metal objects; use tools with insulated handles; wear rubber gloves and boots.
  • 不要把工具或金屬物件放在電池上面;連接或拆除電池端子前,先斷開充電電源。Do not lay tools or metal parts on top of batteries; disconnect the charging source before connecting or disconnecting battery terminals.
  • 不可焚燒、拆開或破壞電池。損壞的電池溫度可能很高,小心燙傷。Do not burn, open or damage batteries. A damaged battery may be very hot; take care to avoid burns.
  • 電池很重,須按安全搬運方法處理。官方數據:Batteries are heavy; use safe handling practices. Official figures:
    • APCRBC140 單個模組約 17 kgAPCRBC140: about 17 kg per module
    • APCRBC152 約 15.3 kgAPCRBC152: about 15.3 kg
    • APCRBC141 約 11.7 kgAPCRBC141: about 11.7 kg
    • 模組上的手柄只用於滑出或推入,不可用來提起搬運。Module handles are only for sliding the module in or out, not for lifting or carrying.
  • 不要使用非 APC 認可的電池:系統無法偵測,可能影響運作,並會令保養失效(990-5269E)。Do not use batteries not approved by APC: the system cannot detect them, operation may be affected, and the warranty is voided (990-5269E).

官方來源:Source: JPS29634 · JPS29632 · 990-5269E · 990-5181B · 990-5299

可否熱插拔(不關機更換)?Hot-swap (replace without shutdown)?

Smart-UPS On-Line SRT(1–10 kVA):手冊形容為「swappable battery modules」(可更換電池模組)。FA333556 指出 SRT/SURT 更換電池模組無需關掉 UPS,但未裝電池期間沒有電池後備。RBC 只應在更換過程中短暫斷開。The manuals describe “swappable battery modules”. FA333556 states that SRT/SURT battery modules can be replaced without turning off the UPS, but there is no battery backup while the batteries are out. RBCs should be disconnected only briefly during replacement.

官方來源:Source: FA333556 · 990-5269E · 990-91070A

步驟概要(SRT,官方手冊)Step overview (SRT, official manuals)

  1. 準備與 UPS 型號相符的新 RBC(見上方對照表)。確認 UPS 已接駁市電,而且輸出正常。Have a new RBC that matches the UPS model (see the table above). Confirm the UPS is connected to utility power and the output is normal.
  2. 拆下前面板(bezel)。如適用,拆除電池倉蓋螺絲(FA333556)。Remove the front bezel. Where applicable, remove the battery compartment cover screws (FA333556).
  3. 拔開 UPS 內電池模組的連接器,把 RBC 從 UPS 滑出。Disconnect the battery module connector inside the UPS and slide the RBC out of the UPS.
  4. 把新 RBC 滑入 UPS,接上電池連接器,並用力推到完全接妥。接觸不良會令 UPS 運作異常、出現異常警報,停電時負載可能得不到電池供電。Slide the new RBC into the UPS, connect the battery connector and push it firmly until it is fully seated. A poor connection can cause erratic UPS operation and false alarms, and the load may not get battery power during an outage.
  5. 如 UPS 顯示屏詢問電池是否全新,全新電池請選 YES,舊電池選 NO。If the UPS display asks whether the battery is new, select YES for a new battery and NO for a used one.
  6. 裝回電池倉蓋及前面板。Refit the battery compartment cover and the front bezel.
  7. 完成後的檢查及設定見下方「更換電池後的設定」。電池首 3 小時約可充至 90%,官方建議充電 24 小時以確保達到完整後備時間。For checks and settings afterwards, see “After replacing the battery” below. The battery charges to about 90% in the first 3 hours; APC recommends charging for 24 hours to ensure full runtime.

官方來源:Source: 990-5269E · 990-91070A · FA333556

完整換電池指引Full replacement guide · 更換後:清除警報、自我測試及校準After replacement: clear alarms, self-test and calibration

APC 通告APC notices

相關 APC 官方通告Related official APC notices

按型號、系列或電池型號篩選;日期以官方頁面為準。最後更新:Filtered by model, series or battery model; dates as shown on the official pages. Last updated: 2026-09-30

查看全部 APC 通告All APC notices

相關型號Related models

使用相同電池的型號Models using the same battery

以下型號同樣使用 APCRBC140:These models also use APCRBC140:

查看 APCRBC140 適用的所有 UPS 型號All UPS models that use APCRBC140